Steam Shower Model Number: ZA218 INSTALLATION AND OWNER'S MANUALPlease carefully read these instructions before you begin to insta
Please read and follow the installation instructions and guidelines in this section.Failure to follow the recommended instructions and installation te
7. CAUTION: The flexible drain should have a level or slight grade to allow free and easy flow to the floor drain. Failure to do so can cau
Electrical RequirementsUnit must be connected by a licensed electrician for your state to a GFCIprotected circuit in order for the warranty to be vali
Install your unit according to the directions in this section in the order presented. Step 1 Install the drainLocate the acce
The base unit is constructed with several leveling feet. Each foot has a lockingnut. Use an adjustable wrench and level to complete this next step.1.
Please see the drain kit diagram provided.1.Place the compression nut onto the flex hose.2. Apply sealant to the drain hose gasket and onto the compre
1.Remove and inspect all of the glass panels. If any are broken, pleasecontact your dealer or the manufacturer.NOTE: The glass panels are labe
4. Apply a liberal bead of sealant on the bottom rail from the slot that receives the glass panel out to the end of the rail.NOTE: The next
1.Open and remove the acrylic back and side panel(s) and inspect fordamage.IMPORTANT: Please note the direction of the screw head. Make sure you can g
additional holes. Be sure to pilot drill the new hole location first before moving to alarger bit. Failure to use a pilot drill can cause the acrylic
Thank you for purchasing your Aston steam shower. We hope that it will provideyou with years of satisfying use and enjoyment. This instruction manual
NOTE: The acrylic wall assembly can be heavy so please use caution when liftingit and placing it onto the base.1. Lift and place the acrylic wall as
NOTE: As with the acrylic assembly, the glass panel assembly is heavy to lift.Please use caution when lifting this assembly and use two people to lif
6. Place the glass panel assembly back onto the base assembly aligning the holes. 7. Using Screw Pack 4 lightly screw the acrylic panels
NOTE: The ceiling panel is large and can be an odd shape. Please use cautionwhen lifting this assembly and use two people to lift it into place.1.Lif
After you have installed and lightly assembled the cabinet walls, you can begin tofully secure all screws and bolts.Tighten the screws in the followi
If your unit includes a decorative trim panel, use the following steps to install thetrim piece.NOTE: There is no need for silicone sealant for this
1. Remove and inspect the glass doors. If any are damaged or broken,please contact your dealer or the manufacturer.2. Determine which door is the r
tube and back plastic washer on the door roller. 5. Taking one of the doors, with the two holes for the door handles located so that
1. The door handles are located within the accessory manual box. Remove them from the packaging and note the end with the knob on it. The
The mounting screws to mount the shower wand holder should already be inplace on the acrylic panel assembly. Remove them for this assembly.1. Assemb
WARNING: To reduce the risk of drowning, electrical shock, or injury, read thefollowing important precautions before using the unit. If you do not fu
1. The shower wand hose has two tapered ends. One end has an O-ring around the outside. This o-ring indicates the end of the hose with the vacuum
1. Unpack the mirror and inspect for damage. If it is broken or damaged,please contact your dealer or the manufacturer.2. Based on your model the m
1.Remove the showerhead from the packaging.2. Install the showerhead onto the showerhead spout located in the center ofthe unit's ceiling. If the
1. Insert the showerhead hose into one of the access holes located in theceiling of the unit.2. Install the elbow/barb fitting provided onto the sh
WARNING: Any final electrical connections must be to a GFCI protected circuitand made by a certified electrician.Based on your unit you may or may no
After completion of the electrical and plumbing connections, we recommend thatyou conduct a system test to ensure all connections are working properly
Before operating this unit ensure you have read and understand all of thewarnings and safety statements in this manual. You can review them now onpage
Over head showerHandheld showerBody & Neck massage jetsCold waterHot waterSteam generatorNote: This diagram is for reference purpose only, and the
Diverter valveThe diverter valve is used to control the flow of water to the following devices: The overhead shower The body jets The shower wan
4. Press the main “on/off” button to turn on the power. 5. Rotate the diverter valve to the overhead shower position. 6. Press the “shower” but
THE FOLLOWING WARNING ONLY APPLY TO UNITS THAT ARE ACOMBINATION STEAM SHOWERS/STEAM BATH UNIT CONTAINING ANATTACHED HYDRO-MASSAGE BATHTUB1.WARNING: To
Body jetsBased on the typical residential water pressure and flow rates not all of the bodyjets can work at the same time. Because of this issue, the
b. Press the shower button to operate the neck jets. c. Press the same local button to turn off the zone. B. Auto Cycle Mod
E. Unconsciousness and danger of drowningTo operate the steam generator use the following instructions :1.Press the main “on/off” button to turn
Light 1. Press the main “on/off” button to turn on the power. 2. Press the “light” button to turn the light on. 3. Press the “light” bu
As with any other luxury item, maintenance and care are critical to the long lastingquality and enjoyment of your steam shower. The proper care and ma
Unscrew the affected jet or showerhead and clean or soak it with a mild solutionof vinegar and water (50/50) or commercially available hard water cle
SymptomsPossible Causes SolutionsNo power to unit 1. Loose powerconnections2. GFCI Breaker tripped3. Internal breaker trip4. Blown fuse5. Missing inte
SymptomsPossible Causes Solutionsthan the internal ambienttemperature, the timesetting must not be zero“0”7. Check the fuses onthe main control boardr
Symptoms Possible Causes SolutionsLight not working 1. Burned out light bulb2. Loose connection1. Replace light bulb2. Repair any looseconnectionsRadi
Symptoms Possible Causes SolutionsNot enough pressure forbody jets, showerhead orshower wand1. Verify your linepressure is 60-80 psi ifnot consult a p
Becoming familiar with commonly used plumbing and electrical terms will help youas you use this owner's manual and when you consult the dealer re
PLEASE READ THESE WARRANTY TERMS AND CONDITIONSCAREFULLY BEFORE USING YOUR ASTON GLOBAL BATHROOMPRODUCT. BY USING THE PRODUCT, YOU ARE CONSENTING TO B
verification that the Product arrived in a good and acceptablecondition); and (b) clearly notate damage on the delivery acknowledgmentreceipt. Failur
allow the exclusion or limitation of incidental or consequential damages, so theabove limitations or exclusions may not apply. No dealer, distributor
Customer Service877-424-9699Aston Global Inc1501 10th St Suite 150PLANO, TX 75074 If further assistance is needed, or you have a
NEC (National Electric Code) (USA) Universal set of standards governing proper electrical installationNeutral
Line (L1) = 110-120 VAC (Black or “Hot 1”) Line (L2) = 110-120 VAC (Red or White or “Hot 2”)
123456789101112131514 1.Light 2.Exhaust Fan 3.Handheld Shower Wand 4.Body Jets 5.Mirror 6.Door Handles 7.Steam Outlet8.Drain9.Speaker10.Rainfal
SUPPLIED HARDWARE SUPPLIED PARTS814M4x16M4x5014SCREW PACK (1)6SCREW PACK (2)84SCREW PACK (3)SCREW PACK (4)M4x306M4x353M4x60M5x25M5x301M5x60SCREW PACK